This document describes how to calculate the rotor frequency of a two-pole, 50 Hz induction motor given the rotor speed of 2850 rpm. It shows that the slip speed is 3000 rpm, the slip percentage is 5%, and using the formula fs x %slip / 100, the rotor frequency is calculated to be 2.5 Hz.